Shutdown Process Of Open Type Rotary Screen Printer

After processing the cloth, the Hot Air Stenterintroduces the cloth guide to the operation table, tears the cloth guide, clicks the red cloth control button to red, and closes the upper needle protection entrance button to "0" to start the second half of the machine.

  1. After processing the cloth, the Hot Air Stenterintroduces the cloth guide to the operation table, tears the cloth guide, clicks the red cloth control button to red, and closes the upper needle protection entrance button to "0" to start the second half of the machine. Stop the cloth guide when it reaches the cloth feed roller, connect the cloth guide to the guide belt, turn off the cooling cylinder tension motor to "0", and start the second half of the machine until the cloth guide completely exits the cloth rack and stop. Turn off the fabric control button to red, and start the machine to let the chain run idle.
  2. Press the oven button to enter the heating system interface, set the heating temperature to 150 degrees, the power of the circulating fan is 50%, the exhaust fan is manually controlled and draws the air with 100% power, so that the residual moisture in the oven can be effectively removed to maintain The role of the oven. After running for about 30 minutes, turn off the heating system, let the circulation fan and the exhaust fan continue to run until the temperature in the oven drops below 100 degrees, and then turn off.
  3. Turn off the main control switch of the power cabinet to "OFF", the computer automatically stores the processing data and then closes, and cleans the Open Type Rotary Screen Printer.